ALDERON FLAT  WALL PANEL

Alderon Flat Wall Panel merupakan panel uPVC inovatif dari PT Unipack Plasindo yang dapat berfungsi sebagai partisi. Dirancang tahan terhadap bahan kimia, peredam panas, anti‑bocor, berbobot ringan, mudah diaplikasikan, serta dapat dilapisi dengan lapisan dekoratif.

Keunggulan Alderon Flat Wall Panel

Excellent Chemical Resistant Properties

Tahan Terhadap Bahan Kimia

Thermal Insulation

Mereduksi Panas

Water Tightness

Anti Bocor

Low Handling Weight

Bobot yang Ringan

alderon flat wall panel

Flat Wall

Panel

Alderon Flat Wall Panel terbuat dari material uPVC yang secara khusus dikembangkan untuk tahan radiasi sinar UV, sehingga melindungi ruang Anda sekaligus memberikan kenyamanan.

Spesifikasi Produk

Lebar Efektif 1000 mm
Berat 5.7 Kg/Lm
Ketebalan 20 mm

Contoh Aplikasi Alderon FWP

  • Panel dinding bangunan area komersial dan industri.
  • Panel partisi portabel untuk ruangan rementara.
  • Panel pabrik makanan dan obat-obatan. 
  • Panel bangunan atau hunian darurat. 
  • Pelapis dinding peternakan.

Sifat Termal

Metode Pengujian Produk Alderon FWP
Konduktivitas Termal ASTM E1530-11 0.27 W/mk
Resistansi Termal ASTM E1530-11 7.13E-2 m2k/w
Suhu -20 to 60 derajat Celcius

Alderon FWP dari konstruksi berongga dan tiga dinding memiliki sifat isolasi panas (dan suara) yang baik. Di atas merupakan data sampel yang diuji dari sifat isolasi dan konduksi sebagai pembanding dengan panel dan dinding lain.

Rentang suhu dari Alderon FWP meliputi -20°C sampai 60 °C, perawatan lebih perlu diberikan saat menggunakan lembar uPVC pada suhu yang lebih rendah; uPVC lebih rentan terhadap benturan pada suhu dibawah 0°C.

Sifat Mudah Terbakar

Alderon FWP dapat memadamkan api sendiri tanpa sumber api eksternal dan memenuhi peringkat tertinggi untuk bahan atap plastik dan komposit. Di bawah Uji Mudah Terbakar UL94, Alderon FWP diklasifikasikan sebagai V-0 dengan sifat mudah terbakar rendah.

Sifat Fisik dan Mekanik

Metode Pengujian Produk Alderon FWP
Tensile Strength at Yield ASTM D-638 30 Mpa
Elongation at Yield ASTM D-638 15%
Hardness ASTM D-2240 79
Modulus of Elasticity in Bending ASTM D-790 750

Ketika memasang Alderon FWP, balok penyangga horizontal perlu dipasang setiap ketinggian 1500mm – 1800mm dan balok vertikal untuk lebar bentang sekitar 2000mm.

Perlu diperhatikan bahwa kekuatan mekanis akan berkurang seiring waktu jika terpapar sinar matahari dan bahan-bahan kimia, dan setelah beberapa tahun (tergantung pada kondisi lokasi) direkomendasikan untuk melakukan inspeksi keutuhan struktur panel kembali.

Ketahanan Terhadap Bahan Kimia dan Korosi

Test Method Produk Alderon FWP
40% Asam Sulfat 60°C 168 jam ASTM D543-06 Tidak ada perubahan
40% Asam Nitrat 60°C 168 jam ASTM D543-06 Tidak ada perubahan
Gas Amonia suhu ruangan 168 hours ASTM D543-06 Tidak ada perubahan

Alderon FCP memiliki ketahanan terhadap bahan kimia yang baik terhadap berbagai bahan-bahan kimia, asam dan basa, terutama bahan kimia pengolahan karet, bahan kimia pembuatan kertas, gas/uap amonia & metana dari hewan dan limbah peternakan, bahan kimia pupuk, asap galvanis, dan lain-lain.

Proses Instalasi

installation alderon flat hollow fwp
Klik gambar untuk memperbesar
  • Pasang modul cladding ke struktur menggunakan sekrup roofing
  • Pasang modul cladding kedua dengan menyambungkan sistem tongue & groove
  • Ulangi langkah untuk memasang modul selanjutnya.

Product Specifications

Effective Width 1000 mm
Weight 5.7 Kg/Lm
Flat Thickness 20 mm

Some examples of Alderon FWP uses

  • Industrial & Commercial building wall panels.
  • Portable partitions panels for temporary rooms.
  • Clean Food & Pharmaceutical factories panels.
  • Emergency housing/building panels.
  • Animal farms insulating & chemical resistant (vs animal waste)wall claddings.

Thermal Properties

Test Method Product Alderon FWP
Thermal Conductivity ASTM E1530-11 0.27 W/mk
Thermal Resistance ASTM E1530-11 7.13E-2 m2k/w
Service Temperature -20 to 60 degree Celcius

 

Alderon FWP being of hollow and triple walled construction is of good thermal (and sound) insulating properties. Above are tested sample data of insulating and conducting properties for comparison with other walls
and panels.

The service temperature range of Alderon FWP is -20°C to 60 °C, greater care should be taken when working with UPVC Sheet at lower temperatures; UPVC is less resistant to impact damage at temperatures below zero
Celsius.

Flammability

Alderon FWP is self-extinguishing without external flame source and conforms with the highest ratings for plastic and composite materials. Under UL94 Flammability Test, Alderon FWP classified as V-0 low flammability.

Physical & Mechanical Properties

Test Method Product Alderon FWP
Tensile Strength at Yield ASTM D-638 30 Mpa
Elongation at Yield ASTM D-638 15%
Hardness ASTM D-2240 79
Modulus of Elasticity in Bending ASTM D-790 750

 

When installing Alderon FWP, horizontal supporting beams should be applied for every 1500 mm – 1800 mm of height and vertical beam for approximately 2000 mm span width.

Please take note that mechanical strength would reduce over time if exposed to sunlight and chemicals, and it is recommended after some years (depending on the location environment) that inspections be carried out
re the structural integrity of the panels.

Corrosion and Chemical Resistance

Test Method Product Alderon FWP
Sulphuric Acid 40% 60 degree Celcius 168 hours ASTM D543-06 No Change
Nitric Acid 40% 60 degree Celcius 168 hours ASTM D543-06 No Change
Ammonia Gas room temperature 168 hours ASTM D543-06 No Change

 

Alderon FWP has good chemical resistance to a wide range of chemicals , acids and bases, especially rubber processing chemicals, paper making chemicals, animal and waste farms methane & ammonia gas/vapour,
fertilizer chemicals, galvanizing fumes etc.

Installation Process

installation alderon flat hollow fwp
Click image to enlarge

 

  • Install the cladding module to the structure using roofing screws.
  • Attach the second cladding module from male to female with the tongue & groove system.
  • Repeat the step to install the next module.
+ Product Specifications

Product Specifications

Effective Width 1000 mm
Weight 5.7 Kg/Lm
Flat Thickness 20 mm

Some examples of Alderon FWP uses

  • Industrial & Commercial building wall panels.
  • Portable partitions panels for temporary rooms.
  • Clean Food & Pharmaceutical factories panels.
  • Emergency housing/building panels.
  • Animal farms insulating & chemical resistant (vs animal waste)wall claddings.
+ Thermal Properties

Thermal Properties

Test Method Product Alderon FWP
Thermal Conductivity ASTM E1530-11 0.27 W/mk
Thermal Resistance ASTM E1530-11 7.13E-2 m2k/w
Service Temperature -20 to 60 degree Celcius

 

Alderon FWP being of hollow and triple walled construction is of good thermal (and sound) insulating properties. Above are tested sample data of insulating and conducting properties for comparison with other walls
and panels.

The service temperature range of Alderon FWP is -20°C to 60 °C, greater care should be taken when working with UPVC Sheet at lower temperatures; UPVC is less resistant to impact damage at temperatures below zero
Celsius.

+ Flammability

Flammability

Alderon FWP is self-extinguishing without external flame source and conforms with the highest ratings for plastic and composite materials. Under UL94 Flammability Test, Alderon FWP classified as V-0 low flammability.

+ Physical & Mechanical Properties

Physical & Mechanical Properties

Test Method Product Alderon FWP
Tensile Strength at Yield ASTM D-638 30 Mpa
Elongation at Yield ASTM D-638 15%
Hardness ASTM D-2240 79
Modulus of Elasticity in Bending ASTM D-790 750

 

When installing Alderon FWP, horizontal supporting beams should be applied for every 1500 mm – 1800 mm of height and vertical beam for approximately 2000 mm span width.

Please take note that mechanical strength would reduce over time if exposed to sunlight and chemicals, and it is recommended after some years (depending on the location environment) that inspections be carried out
re the structural integrity of the panels.

+ Corrosion and Chemical Resistance

Corrosion and Chemical Resistance

Test Method Product Alderon FWP
Sulphuric Acid 40% 60 degree Celcius 168 hours ASTM D543-06 No Change
Nitric Acid 40% 60 degree Celcius 168 hours ASTM D543-06 No Change
Ammonia Gas room temperature 168 hours ASTM D543-06 No Change

 

Alderon FWP has good chemical resistance to a wide range of chemicals , acids and bases, especially rubber processing chemicals, paper making chemicals, animal and waste farms methane & ammonia gas/vapour,
fertilizer chemicals, galvanizing fumes etc.

+ Installation Process

Installation Process

installation alderon flat hollow fwp
Click image to enlarge

 

  • Install the cladding module to the structure using roofing screws.
  • Attach the second cladding module from male to female with the tongue & groove system.
  • Repeat the step to install the next module.

Alderon Flat Wall Panel

Dapatkan informasi lengkap seputar spesifikasi serta fitur-fitur produk Alderon Flat Wall Panel

IKUTI MEDIA SOSIAL ALDERON
white facebook icon
white instagram icon

DAPATKAN PRODUK ALDERON FLAT WALL PANEL SEKARANG JUGA

BERKOMUNIKASI DENGAN KAMI

Ingin mendapatkan produk kami dengan cepat ?

HUBUNGI KAMI

Alderon

Altira Office Tower 37th Floor
Altira Business Park
Jl. Yos Sudarso Kav. 85
Jakarta 14350 - Indonesia

Phone : +6221 2188 2099 / 2001
Fax : +6221 2188 2098 / 2021
Email : cs@impack-pratama.com